7.16.3 Draining charge-air coolant
Preconditions
☑Engine shut down and secured against being restarted.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Sealing ring
(→ Spare Parts Catalog)
WARNING
Coolant is hot and under pressure.
Risk of injury and scalding!
• Let the engine cool down.
• Wear protective clothing, gloves, and goggles / safety mask.
Draining charge-air coolant
1. Have a suitable container ready to catch
the coolant.
2. Turn pressure cap on coolant expansion
tank counterclockwise until the first stop
and allow pressure to escape.
3. Continue to turn pressure cap counter-
clockwise and remove.
4. Draw off separated corrosion inhibitor fluid
in expansion tank through the filler neck.
5. Open drain valves and/or drain plugs and
drain coolant at the following points:
• on the low-temperature coolant pump
• on the low-temperature thermostat
housing.
6. Drain off residual coolant:
• on the intercooler
7. Close all drain valves and screw in drain
plugs using new sealing rings.
8. Place pressure cap on filler neck and close.
134 | Task Description | M015695/03E 2013-03
TIM-ID: 0000007022 - 004
Comentários a estes Manuais